Background: Obstructive sleep apnoea (OSA) is highly prevalent and associated with cardiovascular and metabolic changes. OSA is usually diagnosed by polysomnography which is time-consuming and provides little information on the patient's phenotype thus limiting a personalised treatment approach. Exhaled breath contains information on metabolism which can be analysed by mass spectrometry within minutes. The objective of this study was to identify a breath profile in OSA recurrence by use of secondary-electrospray-ionization-mass spectrometry (SESI-MS).
Methods: Patients with OSA effectively treated with CPAP were randomised to either withdraw treatment (subtherapeutic CPAP) or continue therapeutic CPAP for 2 weeks. Exhaled breath analysis by untargeted SESI-MS was performed at baseline and 2 weeks after randomisation. The primary outcome was the change in exhaled molecular breath pattern.
Results: 30 patients with OSA were randomised and 26 completed the trial according to the protocol. CPAP withdrawal led to a recurrence of OSA (mean difference in change of oxygen desaturation index between groups +30.3/h; 95% CI 19.8/h,40.7/h, p<0.001) which was accompanied by a significant change in 62 exhaled features (16 metabolites identified). The panel of discriminating mass-spectral features allowed differentiation between treated and untreated OSA with a sensitivity of 92.9% and a specificity of 84.6%.
Conclusion: Exhaled breath analysis by SESI-MS allows rapid and accurate detection of OSA recurrence. The technique has the potential to characterise an individual's metabolic response to OSA and thus makes a comprehensible phenotyping of OSA possible.
Trial registration number: NCT02050425 (registered at ClinicalTrials.gov).
Keywords: Exhaled Airway Markers; Sleep apnoea.
Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/