Endovascular repair of pseudoaneurysms after open surgery for aortic coarctation

Interact Cardiovasc Thorac Surg. 2016 Jan;22(1):26-31. doi: 10.1093/icvts/ivv297. Epub 2015 Oct 26.

Abstract

Objectives: To analyse early and long-term results of thoracic endovascular aortic repair (TEVAR) in patients with pseudoaneurysms after open aortic coarctation (CoA) repair.

Methods: A total of 11 patients of 418 patients who had been treated with TEVAR during the period from January 1998 to April 2015 (8 males; median age 53 years) were retrospectively analysed. Dacron patch aortoplasty was primarily performed in 9 patients and subclavian flap aortoplasty in 2 patients. Seven of the 11 patients had asymptomatic pseudoaneurysms (median diameter 56 mm, range 20-65 mm) diagnosed by routine screening. Symptomatic patients presented with haemoptysis, lower limb ischaemia, haemodynamic collapse and back pain and underwent emergency repair (4/11). Adjunctive procedures at the proximal landing zone were required in 7/11 patients. The median number of implanted endoprostheses per patient was 1 (range: 1-5). The median follow-up was 60 months (range 6-161 months).

Results: Technical success was achieved in 91% (10/11; 1 secondary elective open conversion). The 30-day mortality was 0%. The stroke rate was 18% (2 non-disabling strokes). In 2 patients (20%), stent-graft displacement during deployment was observed. The reintervention rate was 33% (Type Ib endoleak, left arm claudication, partial coverage of the left common carotid artery). Clinical success during follow-up was achieved in 10/11 patients. In 9/10 patients, aneurysm sac shrinkage was observed. The Type II endoleak rate was 10% (1/10; intercostal artery). The overall mortality rate was 9% (1 patient died of amyotrophic lateral sclerosis).

Conclusions: Endovascular treatment of post-coarctation pseudoaneurysms is feasible in elective and emergency cases, yielding durable results in the long term. Due to anatomical specifics, implantation may be challenging and requires careful procedural planning. On-site cardiothoracic surgery backup is essential in case open conversion is required.

Keywords: Aorta; Aortic coarctation; Pseudoaneurysm; TEVAR; Thoracic endovascular aortic repair.

MeSH terms

  • Adolescent
  • Adult
  • Aged
  • Aneurysm, False / diagnosis
  • Aneurysm, False / etiology
  • Aneurysm, False / surgery*
  • Aortic Aneurysm, Thoracic / diagnosis
  • Aortic Aneurysm, Thoracic / etiology
  • Aortic Aneurysm, Thoracic / surgery*
  • Aortic Coarctation / surgery*
  • Blood Vessel Prosthesis Implantation / adverse effects*
  • Child
  • Child, Preschool
  • Endovascular Procedures / methods*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Postoperative Complications / diagnosis
  • Postoperative Complications / etiology
  • Postoperative Complications / surgery*
  • Reoperation
  • Retrospective Studies
  • Time Factors
  • Treatment Outcome
  • Young Adult