Objectives: The true impact of postoperative blood pressure (BP) control on development of aortic regurgitation (AR) following continuous-flow left ventricular assist device (CF-LVAD) implantation remains uncertain. This study examines the influence of BP in patients with de novo AR following CF-LVAD implantation.

Methods: All patients with no or <mild AR who underwent CF-LVAD implantation from July 2006 to July 2012 at our institute and with subsequent device-support of ≥3months (n = 90) were studied. Serial echocardiograms and BP readings were obtained preoperatively, postoperatively at 1, 3 and 6 months, and then at a minimum of 4-monthly intervals. BP readings were compared between patients who developed mild AR (AR group) versus those who did not (non-AR group). Logistic regression analysis was used to define independent predictors of ≥mild AR following CF-LVAD implantation.

Results: Median duration of CF-LVAD support was 575 days (range: 98-2433 days). Forty-eight patients (53.3%) developed mild AR over a median duration of 126 days. BP readings (median values, mmHg) between AR and non-AR groups showed statistically significant differences: at 3 months-systolic 99.5 vs 92.5 (P = 0.038), diastolic 81.5 vs 66 (P < 0.001), mean 86.5 vs 74 (P < 0.001) and at 6 months-diastolic 73 vs 62 (P = 0.044), mean 83 vs 74.5 (P = 0.049), respectively. Systolic BP at 3 months (P = 0.047, 95% CI 0.453-0.994, OR 0.671), aortic valve (AoV) closure (P = 0.01, 95% CI 0.002-0.429, OR 0.029) and duration of support (P = 0.04, 95% CI 1.000-1.009, OR 1.004) were found to be independent predictors of AR following CF-LVAD implantation.

Conclusions: BP readings at 3 months and 6 months showed a statistically significant association with ≥mild AR following CF-LVAD implantation, with systolic blood pressure at 3 months, aortic valve closure and longer support duration being independent predictors. Clinical implications of these data may warrant consideration of aggressive early control of BP to protect against the development/progress of AR following CF-LVAD implantation.

Keywords: Aortic regurgitation; Blood pressure; Bridge to transplant; Hypertension; Left ventricular assist device.

MeSH terms

  • Adult
  • Aortic Valve Insufficiency / epidemiology*
  • Blood Pressure / physiology*
  • Female
  • Heart-Assist Devices / adverse effects*
  • Humans
  • Male
  • Middle Aged
  • Postoperative Period
  • Retrospective Studies
  • Risk Factors