Direct immunosensing by spectral correlation interferometry: assay characteristics versus antibody immobilization chemistry

Anal Bioanal Chem. 2015 May;407(14):3955-64. doi: 10.1007/s00216-015-8600-y. Epub 2015 Mar 11.

Abstract

A 3-channel biosensor based on spectral correlation interferometry (SCI) has been adapted for direct optical detection of antigens by measuring changes in thickness of a biolayer on functionalized glass slips employed as affordable single-use sensor chips. The instrument is insensitive to the bulk refractive index of a solution under test and provides signals in metrological units (pm or nm). Using real-time monitoring with the SCI, protocols for fabrication of sensor chips with different functional (epoxylated, carboxylated, and biotinylated) surfaces for antibody immobilization have been developed and optimized to minimize chip-to-chip variations and achieve better limit of detection (LOD), shorter assay time, and longer shelf life. The optimized coupling surfaces have been compared for detection of human serum albumin (HSA) used as a model agent of medical significance. The dynamic ranges for measuring the HSA concentration were 0.07-20, 0.12-30, and 0.25-10 μg/ml, and the assay durations were less than 20, 15, and 30 min for the epoxylated, carboxylated, and biotinylated chips, respectively. The advantages of each type of sensor chip have been shown, namely, the carboxylated chips feature the shortest assay time, the epoxylated ones demonstrate the best LOD, and the biotinylated chips exhibit the longest shelf life in an unprotected environment. The developed protocols of antibody immobilization can be used in different biosensors and assay techniques including those based on fluorescent, magnetic or plasmonic labels, etc. The SCI is well compatible with various partially transparent layers used in biosensing and with microarrays for multi-analyte detection.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Antibodies, Immobilized*
  • Biosensing Techniques / instrumentation*
  • Biosensing Techniques / methods*
  • Humans
  • Interferometry / instrumentation
  • Interferometry / methods*
  • Lab-On-A-Chip Devices
  • Limit of Detection
  • Serum Albumin / chemistry*

Substances

  • Antibodies, Immobilized
  • Serum Albumin