A versatile, stability-indicating and high-throughput ultra-fast liquid chromatography method for the determination of isoflavone aglycones in soybeans, topical formulations, and permeation assays

Talanta. 2015 Mar:134:183-193. doi: 10.1016/j.talanta.2014.10.062. Epub 2014 Nov 11.

Abstract

There is a growing interest in the pharmaceutical field concerning isoflavones topical delivery systems, especially with regard to their skin care properties and antiherpetic activity. In this context, the present work describes an ultra-fast liquid chromatography method (UFLC) for determining daidzein, glycitein, and genistein in different matrices during the development of topical systems containing isoflavone aglycones (IA) obtained from soybeans. The method showed to be specific, precise, accurate, and linear (0.1 to 5 µg mL(-1)) for IA determination in soybean acid extract, IA-rich fraction obtained after the purification process, IA loaded-nanoemulsions, and topical hydrogel, as well as for permeation/retention assays in porcine skin and porcine esophageal mucosa. The matrix effect was determined for all complex matrices, demonstrating low effect during the analysis. The stability indicating UFLC method was verified by submitting IA to acidic, alkaline, oxidative, and thermal stress conditions, and no interference of degradation products was detected during analysis. Mass spectrometry was performed to show the main compounds produced after acid hydrolysis of soybeans, as well as suggest the main degradation products formed after stress conditions. Besides the IA, hydroxymethylfurfural and ethoxymethylfurfural were produced and identified after acid hydrolysis of the soybean extract and well separated by the UFLC method. The method's robustness was confirmed using the Plackett-Burman experimental design. Therefore, the new method affords fast IA analysis during routine processes, extract purification, products development, and bioanalytical assays.

Keywords: Isoflavone aglycones; Matrix effect; Permeation/retention assays; Soybean acid extract; Stability indicating UFLC method; Topical delivery systems.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Administration, Topical
  • Animals
  • Biological Transport
  • Chromatography, High Pressure Liquid / methods*
  • Esophagus / drug effects
  • Esophagus / metabolism
  • Furaldehyde / analogs & derivatives
  • Furaldehyde / chemistry
  • Furaldehyde / isolation & purification
  • Furaldehyde / pharmacology
  • Genistein / chemistry
  • Genistein / isolation & purification*
  • Genistein / pharmacology
  • Glycine max / chemistry*
  • Hydrogels
  • Hydrolysis
  • Isoflavones / chemistry
  • Isoflavones / isolation & purification*
  • Isoflavones / pharmacology
  • Mucous Membrane / drug effects
  • Mucous Membrane / metabolism
  • Permeability
  • Plant Extracts / chemistry
  • Skin / drug effects
  • Skin / metabolism
  • Swine

Substances

  • Hydrogels
  • Isoflavones
  • Plant Extracts
  • daidzein
  • 5-hydroxymethylfurfural
  • glycitein
  • Genistein
  • Furaldehyde