Utility of ⁹⁹mTc-human serum albumin diethylenetriamine pentaacetic acid SPECT for evaluating endoleak after endovascular abdominal aortic aneurysm repair

AJR Am J Roentgenol. 2015 Jan;204(1):189-96. doi: 10.2214/AJR.13.12383.

Abstract

Objective: The purpose of this study was to assess the utility of (99m)Tc-human serum albumin diethylenetriamine pentaacetic acid ((99m)Tc-HSAD) SPECT in the detection of endoleaks after endovascular abdominal aortic aneurysm repair.

Subjects and methods: Fifteen patients (11 men, four women) with aneurysm sac expansion of 5 mm or greater after endovascular abdominal aortic aneurysm repair underwent three-phase CT, (99m)Tc-HSAD SPECT, and CT during aortography. Sensitivity calculations for three-phase CT and (99m)Tc-HSAD SPECT were performed with CT during aortography as the reference standard. The volume of each endoleak was measured with CT during aortography. Seven subjects underwent embolization with N-butyl cyanoacrylate (NBCA)-Lipiodol (ethiodized oil, Guerbet and metallic coils. Three-phase CT and (99m)Tc-HSAD SPECT were repeated after embolization to assess their efficacy.

Results: Endoleaks were interpreted as perigraft radioisotope accumulation in 12 patients (80.0%) on (99m)Tc-HSAD SPECT images, in 13 patients (86.7%) on three-phase CT images, and in 15 patients (100%) on CT during aortography. The mean endoleak volume visualized with (99m)Tc-HSAD SPECT was 8.37 cm(3) (range, 5.2-15.1 cm(3)), and the volume not visualized was 3.47 cm(3) (2.5-4.6 cm(3)), a statistically significant difference (p = 0.019). In two patients, (99m)Tc-HSAD SPECT depicted endoleaks evident at delayed phase CT during aortography but not at three-phase CT, suggesting they were slow-filling endoleaks. Accumulation of (99m)Tc-HSAD corresponding to endoleaks disappeared after embolization, but CT evaluation of embolization was impeded by artifacts of NBCA-Lipiodol and metallic coils.

Conclusion: Technetium-99m-labeled HSAD SPECT proved less sensitive than three-phase CT but depicted endoleaks with volumes 5.2 cm(3) or greater as perigraft radioisotope accumulation. Slow-filling endoleaks can be visualized with (99m)Tc-HSAD SPECT, which can be used to evaluate the efficacy of embolization.

Keywords: 99mTc-HSAD; abdominal aortic aneurysm; embolization; endoleak; endovascular abdominal aortic aneurysm repair.

Publication types

  • Clinical Trial

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / complications
  • Aortic Aneurysm, Abdominal / diagnostic imaging*
  • Aortic Aneurysm, Abdominal / surgery*
  • Endoleak / diagnostic imaging*
  • Endoleak / etiology*
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation
  • Female
  • Humans
  • Male
  • Middle Aged
  • Radiopharmaceuticals
  • Reproducibility of Results
  • Sensitivity and Specificity
  • Stents / adverse effects*
  • Technetium Tc 99m Aggregated Albumin*
  • Technetium Tc 99m Pentetate*
  • Tomography, Emission-Computed, Single-Photon / methods*
  • Treatment Outcome

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Aggregated Albumin
  • technetium Tc 99m DTPA HSA
  • Technetium Tc 99m Pentetate