Intra-individual comparison of magnesium citrate and sodium phosphate for bowel preparation at CT colonography: automated volumetric analysis of residual fluid for quality assessment

Clin Radiol. 2014 Nov;69(11):1171-7. doi: 10.1016/j.crad.2014.08.001. Epub 2014 Sep 18.

Abstract

Aim: To perform an objective, intra-individual comparison of residual colonic fluid volume and attenuation associated with the current front-line laxative magnesium citrate (MgC) versus the former front-line laxative sodium phosphate (NaP) at CT colonography (CTC).

Materials and methods: This retrospective Health Insurance and Portability and Accountability Act-compliant study had institutional review board approval; informed consent was waived. The study cohort included 250 asymptomatic adults (mean age at index 56.1 years; 124 male/126 female) who underwent CTC screening twice over a 5 year interval. Colon catharsis at initial and follow-up screening employed single-dose NaP and double-dose MgC, respectively, allowing for intra-patient comparison. Automated volumetric analysis of residual colonic fluid volume and attenuation was performed on all 500 CTC studies. Colonic fluid volume <200 ml and mean attenuation between 300-900 HU were considered optimal. Paired t-test and McNemar's test were used to compare differences.

Results: Residual fluid volumes <200 ml were recorded in 192 examinations (76.8%) following MgC and in 204 examinations (81.6%) following NaP (p = 0.23). The mean total residual fluid volume was 155 ± 114 ml for MgC and 143 ± 100 ml for NaP (p = 0.01). The attenuation range of 300-900 HU was significantly more frequent for MgC (n = 220, 88%) than for NaP (n = 127, 50.8%; p < 0.001). Mean fluid attenuation was significantly lower for MgC (700 ± 165 HU) than for NaP (878 ± 155 HU; p < 0.001). Concomitant presence of both optimal fluid volume and attenuation was significantly more frequent for MgC 65.2% than for NaP (38%; p < 0.001).

Conclusions: Objective intra-individual comparison using automated volumetric analysis suggests that the replacement of NaP by MgC as the front-line laxative for CTC has not compromised overall examination quality.

Publication types

  • Comparative Study
  • Research Support, N.I.H., Extramural

MeSH terms

  • Aged
  • Cathartics / administration & dosage*
  • Citric Acid / administration & dosage*
  • Colonography, Computed Tomographic*
  • Female
  • Humans
  • Male
  • Middle Aged
  • Organometallic Compounds / administration & dosage*
  • Phosphates / administration & dosage*
  • Quality Assurance, Health Care
  • Radiographic Image Interpretation, Computer-Assisted
  • Retrospective Studies
  • Software

Substances

  • Cathartics
  • Organometallic Compounds
  • Phosphates
  • Citric Acid
  • magnesium citrate
  • sodium phosphate