Purpose: To determine how the respiratory phase impacts dose to normal organs during stereotactic body radiation therapy (SBRT) for pancreatic cancer.
Methods and materials: Eighteen consecutive patients with locally advanced, unresectable pancreatic adenocarcinoma treated with SBRT were included in this study. On the treatment planning 4-dimensional computed tomography (CT) scan, the planning target volume (PTV), defined as the gross tumor volume plus 3-mm margin, the duodenum, and the stomach were contoured on the end-expiration (CTexp) and end-inspiration (CTinsp) phases for each patient. A separate treatment plan was constructed for both phases with the dose prescription of 33 Gy in 5 fractions with 95% coverage of the PTV by the 100% isodose line. The dose-volume histogram (DVH) endpoints, volume of duodenum that received 20 Gy (V20), V25, and V30 and maximum dose to 5 cc of contoured organ (D5cc), D1cc, and D0.1cc, were evaluated.
Results: Dosimetric parameters for the duodenum, including V25, V30, D1cc, and D0.1cc improved by planning on the CTexp compared to those on the CTinsp. There was a statistically significant overlap of the PTV with the duodenum but not the stomach during the CTinsp compared to the CTexp (0.38 ± 0.17 cc vs 0.01 ± 0.01 cc, P=.048). A larger expansion of the PTV, in accordance with a Danish phase 2 trial, showed even more overlapping volume of duodenum on the CTinsp compared to that on the CTexp (5.5 ± 0.9 cc vs 3.0 ± 0.8 cc, P=.0003) but no statistical difference for any stomach dosimetric DVH parameter.
Conclusions: Dose to the duodenum was higher when treating on the inspiratory than on the expiratory phase. These data suggest that expiratory gating may be preferable to inspiratory breath-hold and free breathing strategies for minimizing risk of toxicity.
Copyright © 2013 Elsevier Inc. All rights reserved.