Sequential sampling from animals challenged with highly pathogenic organisms, such as haemorrhagic fever viruses, is required for many pharmaceutical studies. Using the guinea pig model of Ebola virus infection, a catheterized system was used which had the benefits of allowing repeated sampling of the same cohort of animals, and also a reduction in the use of sharps at high biological containment. Levels of a PS-targeting antibody (Bavituximab) were measured in Ebola-infected animals and uninfected controls. Data showed that the pharmacokinetics were similar in both groups, therefore Ebola virus infection did not have an observable effect on the half-life of the antibody.
Copyright © 2012 Elsevier B.V. All rights reserved.