A minimal extracorporeal circuit has been shown to decrease the transfusion rate, cardiac and neurological damage in coronary surgery. We describe in detail a technique for minimal-access aortic valve replacement using a minimal extra-corporeal circuit, and provide surgical and perfusion tips to maintain antegrade perfusion and a clear surgical field.