In the life cycle of engineered nanoparticles (ENP), their manufacturing requires particular attention because of unwanted potential ENP emissions to workplaces. We simulated three scenarios of equipment failure during gas phase production of nanoparticles in a laboratory. The emission plume of nanoparticles was tracked with high spatial and temporal resolution by 10 measurement devices. While under normal production conditions, no elevated ENP concentrations were observed, worst case scenarios led to homogeneous indoor ENP concentrations of up to 10(6)cm(-3) in a 300m(3) production room after only 60s. The fast dispersal in the room was followed by an exponential decrease in number concentration after the emission event. Under conditions like those observed - rapid dispersal and good mixing - a single measurement device alone can provide valuable information for an ENP exposure assessment. A one-box model adequately reflected measured number concentrations (r(2)>0.99). The ENP emission rates to the workplace were estimated between 2.5·10(11) and 6·10(12)s(-1) for the three emission scenarios. The worst case emission rate at the production zone was also estimated at 2·10(13)s(-1) with a stoichiometric calculation based on the precursor input, density and particle size. ENP intake fractions were 3.8-5.1·10(-4) inhaled ENP per produced ENP in the investigated setting. These could only be substantially lowered by leaving the production room within a few minutes after the emission event.
Copyright © 2012 Elsevier B.V. All rights reserved.