Background: The indirect antiglobulin test (IAT) can be potentiated by agents such as polyethylene glycol (PEG-IAT) and albumin (Alb-IAT). PEG-IAT is generally regarded as superior to Alb-IAT for the detection of clinically significant red blood cell (RBC) antibodies. However, supporting data come from Caucasian-dominant populations. Non-Caucasian populations should be investigated as well.
Material and methods: In this single-centre, retrospective, sequential study, Alb-IAT was used from 1989 to 1996 (8 years) and PEG-IAT from 1997 to 2008 (12 years). Pre-transfusion RBC alloantibody detection rates and specificity, post-transfusion alloantibody production, and the incidence of delayed haemolytic transfusion reaction were assessed and compared for the two periods.
Results: Although overall RBC alloantibody detection rates were comparable, PEG-IAT more frequently detected clinically significant antibodies such as anti-E, anti-Fy(b), and anti-Jk(a), and less frequently detected insignificant antibodies such as anti-Le(b) and anti-P(1). New alloantibodies emerged comparably during the two periods. Delayed haemolytic transfusion reaction was less frequent during the PEG-IAT period (0.30% versus 0.12%, p<0.05).
Conclusion: PEG-IAT was superior in the detection of clinically significant antibodies, reduced the detection of insignificant antibodies, and prevented delayed haemolytic transfusion reaction better than Alb-IAT among Japanese transfusion recipients in this retrospective survey of limited power.