Safety and feasibility of balloon-expandable stent implantation for the treatment of type I endoleaks following endovascular aortic abdominal aneurysm repair

EuroIntervention. 2011 Jan;6(6):740-3. doi: 10.4244/EIJV6I6A125.

Abstract

Aims: The occurrence of type I endoleaks represent an ominous sign after endovascular aneurysms repair (EVAR). We report our experience using balloon-expandable stents (BES) for the treatment of proximal Type I endoleaks at five high-volume hospitals in Argentina.

Methods and results: Of 1,395 patients who underwent EVAR, we retrospectively collected data of 29 (2%) consecutive patients who underwent additional BES to repair proximal type I endoleaks. The mean age was 75.8 years old (range 63-87) and 93% were male. A hostile anatomy was found in 89.6% of the cases. BES oversize (balloon/neck diameter ration ≥ 30%) was frequent (69%); whereas, BES/prosthesis diameter ratio was less than 1 in 79% of the cases. Complete and partial sealing was obtained 72 and 28% of the cases, respectively. There were no immediate or late surgical conversion or major complications related with stent implantation. At a median time follow-up of 14.9 months (25-75% interquartiles: 4.5-17.5 months), there were no cardiovascular deaths, evidence of aneurysm sac enlargement or need for re-intervention.

Conclusions: Our preliminary results suggest that BES implantation for the treatment of proximal type I endoleaks is feasible and safe with favourable mid-term results and may preclude the need for surgical conversion.

Publication types

  • Multicenter Study

MeSH terms

  • Aged
  • Aged, 80 and over
  • Aortic Aneurysm, Abdominal / diagnostic imaging
  • Aortic Aneurysm, Abdominal / surgery*
  • Aortography / methods
  • Argentina
  • Blood Vessel Prosthesis Implantation / adverse effects
  • Blood Vessel Prosthesis Implantation / instrumentation*
  • Blood Vessel Prosthesis*
  • Catheterization*
  • Endoleak / diagnostic imaging
  • Endoleak / etiology
  • Endoleak / therapy*
  • Endovascular Procedures / adverse effects
  • Endovascular Procedures / instrumentation*
  • Feasibility Studies
  • Female
  • Humans
  • Male
  • Middle Aged
  • Retrospective Studies
  • Stents*
  • Time Factors
  • Tomography, X-Ray Computed
  • Treatment Outcome