A method for the simultaneous determination of pregnenolone and 17α-hydroxypregnenolone by high-performance liquid chromatography with an immobilized cholesterol oxidation enzyme reactor was developed. Pregnenolone and 17α-hydroxypregnenolone were converted to progesterone and 17α-hydroxyprogesterone, respectively, by the immobilized enzyme packed into the reactor column, and could thus be monitored by UV absorption at 240 nm. The calibration curves for pregnenolone and 17α-hydroxypregnenolone were linear in the range of 0.4-10 and 0.3-10 μg/ml with a correlation coefficient of 0.9993 and 0.9998, respectively. The detection limit at a signal-to-noise ratio of 3 was 0.12 and 0.08 μg/ml for pregnenolone and 17α-hydroxypregnenolone, respectively. The conversion rate of pregnenolone to progesterone and 17α-hydroxypregnenolone to 17α-hydroxyprogesterone was 90.6% and 99.3%, respectively. Intra-day and inter-day precision (in terms of percentage coefficient of variation) were less than 9.3%, with accuracy greater than 94.8%. This method was successfully applied to the simultaneous determination of pregnenolone and 17α-hydroxypregnenolone secreted into the culture medium of bovine adrenal fasciculata cells and of both analytes produced within the cells.
Copyright © 2010 Elsevier B.V. All rights reserved.