Heparin-induced thrombocytopenia: towards standardization of platelet factor 4/heparin antigen tests

J Thromb Haemost. 2010 Sep;8(9):2025-31. doi: 10.1111/j.1538-7836.2010.03974.x.

Abstract

Background: Laboratory confirmation of heparin-induced thrombocytopenia (HIT) is based on detection of heparin-dependent platelet-activating antibodies. Platelet factor 4 (PF4)/heparin enzyme-immunoassays (EIA) are a widely available surrogate for platelet-activating antibodies.

Objective: Defining the optical density (OD) reactivity profiles of a PF4/heparin EIA in reference subject and patient populations and the correlation of the EIA results (expressed in OD units) with the prevalence of platelet-activating antibodies.

Patients/methods: Using quantile regression we determined the 97.5th percentile of PF4/heparin-immunoglobulin G (IgG) EIA reactivities in non-heparin-treated individuals [blood donors (n = 935)] and patients before heparin therapy (n = 1207). In patients with suspected HIT, we compared the correlation of EIA-IgG reactivities (Greifswald laboratory; n = 2821) and the heparin-induced platelet activation assay (HIPA) with the correlation of reactivities of another EIA-IgG (McMaster laboratory; n = 1956) with the serotonin-release assay (SRA).

Results: PF4/heparin-IgG EIA OD reactivities had a lower OD 97.5th percentile in blood donors compared with patient groups before heparin treatment (P < 0.001). The percentage of sera testing positive in the functional assays strongly correlated with PF4/heparin-IgG EIA OD reactivities in both laboratories with very similar results (correlation coefficient > 0.9) when normalized OD ranges (maximum OD divided by 10) were used instead of absolute OD values.

Conclusions: Results of PF4/heparin-IgG EIA should not be reported as only positive or negative as there is no single acceptable cut-off value. Instead, reporting PF4/heparin-IgG EIA OD results in ranges allows for risk-stratified prediction for presence of platelet-activating antibodies. Use of normalized OD ranges permits a standardized approach for inter-laboratory comparisons.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Adult
  • Aged
  • Female
  • Heparin / adverse effects
  • Heparin / chemistry*
  • Heparin / pharmacology*
  • Humans
  • Immunoenzyme Techniques / methods
  • Immunoglobulin G / chemistry
  • Male
  • Middle Aged
  • Platelet Factor 4 / chemistry*
  • Reference Values
  • Regression Analysis
  • Reproducibility of Results
  • Risk
  • Serotonin / chemistry
  • Sex Factors
  • Thrombocytopenia / metabolism*

Substances

  • Immunoglobulin G
  • Serotonin
  • Platelet Factor 4
  • Heparin