Echocardiographic assessment of pulmonary vascular resistance in pulmonary arterial hypertension

Cardiovasc Ultrasound. 2010 Jun 7:8:21. doi: 10.1186/1476-7120-8-21.

Abstract

Background: Echocardiographic ratio of peak tricuspid regurgitant velocity to the right ventricular outflow tract time-velocity integral (TRV/TVI rvot) was presented as a reliable non-invasive method of estimating pulmonary vascular resistance (PVR). Studies using this technique in patients with moderate to high PVR are scarce. Left ventricular outflow tract time-velocity integral (TVI lvot) can be easier to measure than TVI rvot, especially in patients with severe pulmonary hypertension (PH) with significant anatomical modifications of the right structures.

Aims: We wanted to determine whether the TRV/TVI rvot and TRV/TVI lvot ratios would form a reliable non-invasive tool to estimate PVR in a cohort of patients with moderate to severe pulmonary vascular disease.

Methods: Doppler echocardiographic examination and right heart catheterisation were performed in 37 patients. Invasive PVR was compared with TRV/TVI rvot and TRV/TVI lvot ratios using regression analysis. Two equations were modelled and the results compared with invasive measurements using the Bland-Altman analysis. Using receiver-operating characteristics curve analysis, a cut-off value for the two ratios was generated.

Results: Correlation coefficients between invasive PVR and TRV/TVI rvot then TRV/TVI lvot were respectively 0.76 and 0.74. Two new equations were found but the Bland-Altman analysis showed wide standard deviations (respectively 3.8 and 3.9 Wood units). A TRV/TVI rvot then TRV/TVI lvot ratio cut-off value of 0.14 had a sensitivity of 93% and a specificity of 57% for the first and a sensitivity of 87% and a specificity of 57% for the second to determine PVR > 2 Wood units.

Conclusion: Echocardiography is useful for the screening of patients with pulmonary hypertension and PVR > 2 WU. It remains disappointing for accurate assessment of high PVR. TVI lvot may be an alternative to TVI rvot for patients for whom accurate TVI rvot measurement is not possible.

MeSH terms

  • Blood Flow Velocity
  • Cardiac Catheterization
  • Echocardiography, Doppler
  • Female
  • Humans
  • Hypertension, Pulmonary / diagnostic imaging*
  • Hypertension, Pulmonary / physiopathology*
  • Male
  • Middle Aged
  • ROC Curve
  • Sensitivity and Specificity
  • Vascular Resistance*