Haemolysis index--an estimate of preanalytical quality in primary health care

Clin Chem Lab Med. 2009;47(8):940-4. doi: 10.1515/CCLM.2009.227.

Abstract

Background: Haemolysis is usually caused by inadequate specimen collection or preanalytical handling, and is suggested to be a suitable indicator of pre-analytical quality. We investigated the prevalence of detectable haemolysis in all routine venous blood samples to identify differences in preanalytical quality.

Methods: Haemolysis index (HI) values were obtained from a Vitros 5,1 in the routine clinical chemistry laboratory for samples collected in primary health care centres (PHCs), nursing homes, and a hospital emergency department (ED). Haemolysis was defined as a HI > or =15 (detection limit).

Results: Samples from the PHC with the highest prevalence of haemolysis were 6.1 times (95% confidence interval (CI) 4.0-9.2) more often haemolysed compared to the centre with the lowest prevalence. Of the samples collected in primary health care, 10.4% were haemolysed compared to 31.1% in the ED (p<0.001). A notable difference in haemolysed samples was found between the ED section staffed by emergency medicine physicians and the section staffed by primary health care physicians (34.8% vs. 11.3%, p<0.001).

Conclusions: The significant variation in haemolysis indices among the investigated units is likely to reflect varying preanalytical conditions. The HI is a valuable tool for estimation and follow-up of preanalytical quality in primary health care.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Blood Specimen Collection / standards*
  • Female
  • Hemolysis / physiology*
  • Humans
  • Laboratories, Hospital / statistics & numerical data
  • Male
  • Middle Aged
  • Osmotic Fragility
  • Primary Health Care / standards*
  • Quality Assurance, Health Care / standards