Long-term follow-up of supra-annular pulmonary autograft aortic root replacement in patients with bicuspid aortic valve

Eur J Cardiothorac Surg. 2008 Sep;34(3):583-8; discussion 588. doi: 10.1016/j.ejcts.2008.05.056. Epub 2008 Jul 29.

Abstract

Objective: The performance of the Ross procedure in the case of geometric mismatch between pulmonary autograft and a bicuspid aortic root has not yet been fully evaluated. To prevent geometrically caused autograft dysfunction, a modification of the surgical technique is necessary.

Methods: Between January 1996 and January 2007, 50 patients (33 male, 17 female; mean age 50+/-14 years; range 13-63 years) underwent replacement of a diseased bicuspid aortic valve (stenosis in 14 cases; insufficiency in 21; combined disease in 15) with a Ross procedure. The pulmonary autograft was inserted partially in supra-annular position to correct the geometric mismatch between the deeper base of the non-coronary sinus and the right/left coronary sinus. In 24 of these patients, additional tailoring of the non-coronary sinus was necessary. In eight patients the non-coronary sinus was covered with a glutaraldehyde treated autologous pericardial patch to prevent pseudoaneurysm formation. Patients were followed up 1, 2, 5 and 10 years postoperatively.

Results: There were no early or late deaths. There were six reoperations. One patient was reoperated because of persistent severe aortic valve insufficiency 9 months postoperatively. Three patients were reoperated for formation of subannular pseudoaneurysm, 6, 9 and 30 months postoperatively. One patient was reoperated for closure of a paravalvular dehiscence. Another patient was reoperated 1 year postoperatively because of a severe pulmonary stenosis due to excessive calcification of the bioprosthesis. Echocardiographic follow-up of the remaining patients showed no evidence of residual or recurrent pulmonary autograft regurgitation or progression of aortic root dilatation.

Conclusion: Autograft replacement of the bicuspid aortic valve is challenging, as the geometric mismatch has to be adjusted. Valve dysfunction is avoided by a supra-annular implantation technique, but pseudoaneurysm formation at the base of the non-coronary sinus is a worrying aspect. Patch reinforcement may solve this issue.

Publication types

  • Evaluation Study

MeSH terms

  • Adolescent
  • Adult
  • Aortic Valve / abnormalities
  • Aortic Valve / diagnostic imaging
  • Aortic Valve / pathology
  • Aortic Valve / surgery*
  • Aortic Valve Insufficiency / diagnostic imaging
  • Aortic Valve Insufficiency / surgery
  • Aortic Valve Stenosis / surgery
  • Bioprosthesis
  • Female
  • Follow-Up Studies
  • Heart Valve Prosthesis
  • Heart Valve Prosthesis Implantation / methods*
  • Humans
  • Male
  • Middle Aged
  • Prospective Studies
  • Pulmonary Valve / transplantation*
  • Reoperation / methods
  • Treatment Outcome
  • Ultrasonography
  • Young Adult