A simple method to wrap the graft in repair of acute aortic dissection was described. The diseased ascending aorta was excised and both ends of the aorta were trimmed with application of a Teflon felt inside and a preserved equine pericardium outside. The graft was anastomosed to the trimmed ends and the equine pericardiums were turned and sutured around the graft. Two additional sutures were tied around the equine pericardium to reinforce oppression. This simple technique is very useful to control oozing from the suture lines.