Evaluation of matrix metalloproteinase 7 in plasma and pancreatic juice as a biomarker for pancreatic cancer

Cancer Epidemiol Biomarkers Prev. 2007 May;16(5):886-91. doi: 10.1158/1055-9965.EPI-06-0779.

Abstract

Differentiating between periampullary carcinoma and chronic pancreatitis with an inflammatory mass is difficult. Consequently, 6% to 9% of pancreatic resections for suspected carcinoma are done inappropriately for chronic pancreatitis. Here, we test if matrix metalloproteinase 7 (MMP-7), a secreted protease frequently expressed in pancreatic carcinoma, can be measured in plasma, pancreatic, and duodenal juice, and if it can distinguish between periampullary carcinoma and chronic pancreatitis. Ninety-four patients who underwent pancreatic surgery for a (peri)pancreatic neoplasm (n = 63) or chronic pancreatitis (n = 31) were analyzed. Median plasma MMP-7 levels were significantly higher in carcinoma (1.95 ng/mL; interquartile range, 0.81-3.22 ng/mL) compared with chronic pancreatitis and benign disease (0.83 ng/mL; interquartile range, 0.25-1.21 ng/mL; P < 0.01). MMP-7 levels in pancreatic juice were higher, although not significantly, in carcinoma (62 ng/mg protein; interquartile range, 18-241 ng/mg protein) compared with chronic pancreatitis and benign disease (23 ng/mg protein; interquartile range, 8.5-99 ng/mg protein; P = 0.17). MMP-7 levels in duodenal juice were universally low. At an arbitrary cutoff of 1.5 ng/mL in plasma, positive and negative predictive values were 83% and 57%, respectively, values comparable to those of today's most common pancreatic tumor marker, carbohydrate antigen 19-9 (CA19-9; 83% and 53%, respectively). Positive and negative likelihood ratios for plasma MMP-7 were 3.35 and 0.52, respectively. The area under the receiver operating characteristic curve for MMP-7 was 0.73 (95% confidence interval, 0.63-0.84) and for CA19-9, 0.75 (95% confidence interval, 0.64-0.85). Combined MMP-7 and CA19-9 assessment gave a positive predictive value of 100%. Thus, plasma MMP-7 levels discriminated between patients with carcinoma and those with chronic pancreatitis or benign disease. The diagnostic accuracy of plasma MMP-7 alone is not sufficient to determine treatment strategy in patients with a periampullary mass, but combined evaluation of plasma MMP-7 with CA19-9 and other markers may be clinically useful.

Publication types

  • Research Support, N.I.H., Extramural

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Area Under Curve
  • Biomarkers, Tumor / analysis*
  • Biomarkers, Tumor / blood
  • CA-19-9 Antigen / blood
  • Carcinoma / blood
  • Carcinoma / diagnosis*
  • Diagnosis, Differential
  • Female
  • Humans
  • Male
  • Matrix Metalloproteinase 7 / analysis*
  • Matrix Metalloproteinase 7 / blood
  • Middle Aged
  • Pancreatic Juice / enzymology*
  • Pancreatic Neoplasms / blood
  • Pancreatic Neoplasms / diagnosis*
  • Pancreatitis, Chronic / diagnosis
  • ROC Curve

Substances

  • Biomarkers, Tumor
  • CA-19-9 Antigen
  • Matrix Metalloproteinase 7