Abstract
Results from two dengue rapid tests, the PanBio Duo cassette and the SD Bioline strip test, were compared to those of enzyme-linked immunosorbent assays (Focus Diagnostics) from sera of 200 Vietnamese febrile patients. The PanBio assay was superior, with sensitivity and specificity values for acute-phase serum samples of 54% and 70% (immunoglobulin M) and 70% and 88% (immunoglobulin G), respectively.