Sandwich-enzyme immunoassays (sandwich-EIAs) for endothelin-1 (ET-1), endothelin-3 (ET-3), big ET-1, big endothelin-2 (big ET-2), and big endothelin-3 (big ET-3) have been established using two antibodies directed against the N-terminal and C-terminal portions of each ET and big ET. These sandwich-EIAs are sensitive enough to detect 0.1-0.4 pg/well of each ET or big ET with cross-reactivity of less than 1% with other ETs and big ETs (except in the case of the EIA for ET-1, which detects immunoreactivity of ET-2 as well as ET-1). Plasma levels of immunoreactive (ir-) ET-1, big ET-1, and ET-3 in normal humans were approximately 2.0, 5.1, and 0.9 pg/ml, respectively, when corrected for recovery efficiency. In reverse-phase high-performance liquid chromatography (HPLC) analysis, immunoreactivities detected by these sandwich-EIAs were eluted at the positions of authentic ET-1, big ET-1, and ET-3, indicating that plasma levels of ET-1, big ET-1, and ET-3 were precisely measured by our methods. Levels of ir-big ET-2 and ir-big ET-3 were also detected in normal human plasma; however, further studies are needed to determine their precise values. The establishment of reliable sandwich-EIAs and the measurement of specific ETs and big ETs in normal human plasma will contribute to clarifying the biological and clinical significance of ET family peptides.