Comparison of 99mTc-DTPA renal dynamic imaging with modified MDRD equation for glomerular filtration rate estimation in Chinese patients in different stages of chronic kidney disease

Nephrol Dial Transplant. 2007 Feb;22(2):417-23. doi: 10.1093/ndt/gfl603. Epub 2006 Oct 19.

Abstract

Background: The renal dynamic imaging method (modified Gate's method) with (99m)Tc-diethylene triamine pentaacetic acid ((99m)Tc-DTPA) is simple and less time consuming for glomerular filtration rate (GFR) estimation than other methods. However, its diagnostic performance as a surrogate marker of GFR is questioned increasingly. Recently, the modified Modification of Diet in Renal Disease (MDRD) study equation based on data from Chinese patients of chronic kidney disease (CKD) showed significant performance improvement. In the present study, the renal dynamic imaging methods and the modified abbreviated MDRD equation were compared with the plasma clearance method.

Methods: Four hundred and eighty two patients with CKD were selected. GFR were estimated simultaneously using three methods: (i) modified Gate's method (gGFR); (ii) the modified abbreviated MDRD equation (c-aGFR) and (iii) dual plasma sampling method (rGFR). Using rGFR as the reference method, gGFR and c-aGFR were compared with rGFR in each stage of CKD.

Results: Both gGFR and c-aGFR were correlated well with rGFR (r(gGFR) = 0.81 and r(c-aGFR) = 0.90, P < 0.001). In the overall performance, c-aGFR had less bias (849.5 vs 933.1 arbitrary units), higher precision (57 vs 78.4 ml/min/1.73 m(2)) and higher accuracy than gGFR. For gGFR, the 15, 30 and 50% accuracies were 32.4, 56.0 and 79.1%, respectively; for c-aGFR, the corresponding accuracy rose to 43.2%, 75.5% and 90.9%, respectively. In each stage of CKD, the modified abbreviated MDRD equation also outperformed the modified Gate's method in the GFR estimation.

Conclusion: Our results indicated that the performance of the renal dynamic imaging in total GFR estimation was not better than the modified abbreviated MDRD equation in our patient group, and should not be used as a surrogate marker of GFR, especially in clinical trials. We presume that the dynamic renal imaging methods for estimation of GFR can be improved by using proper reference GFR, more adequate background subtraction and soft-tissue attenuation correction, in a relatively larger sample size.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Asian People*
  • China / epidemiology
  • Disease Progression
  • Follow-Up Studies
  • Humans
  • Kidney Failure, Chronic* / diagnostic imaging
  • Kidney Failure, Chronic* / diet therapy
  • Kidney Failure, Chronic* / epidemiology
  • Male
  • Middle Aged
  • Prevalence
  • Radiopharmaceuticals*
  • Reproducibility of Results
  • Technetium Tc 99m Pentetate*
  • Tomography, Emission-Computed, Single-Photon / methods

Substances

  • Radiopharmaceuticals
  • Technetium Tc 99m Pentetate