Biventricular diastolic filling patterns after coronary artery bypass graft surgery

J Thorac Cardiovasc Surg. 2006 May;131(5):1080-6. doi: 10.1016/j.jtcvs.2006.01.015.

Abstract

Objective: We sought to study the evolution of biventricular filling properties after coronary artery bypass grafting.

Background: The evolution of diastolic function as defined with newer echocardiographic modalities after coronary artery bypass grafting surgery is unknown in patients with preoperative left ventricular diastolic dysfunction.

Methods: Transthoracic echocardiography was performed preoperatively and 48 hours and 6 months after coronary artery bypass grafting in 49 patients (randomized to milrinone [n = 25]) or placebo [n = 24]) with preoperative left ventricular diastolic dysfunction classified according to published criteria. Mild right ventricular diastolic dysfunction was defined as the ratio of early to atrial filling velocity of less than 1 in transtricuspid flow or the velocity of reversed atrial flow of greater than 50% of that of systolic flow in hepatic venous flow or the ratio of tricuspid annulus velocity during early and atrial filling of less than 1 if both the ratio of early to atrial filling velocity and the ratio of systolic to diastolic velocity was greater than 1 in hepatic venous flow. Moderate right ventricular diastolic dysfunction was diagnosed when there was a ratio of early to atrial filling velocity of greater than 1 with a ratio of systolic to diastolic velocity of less than 1. Severe right ventricular diastolic dysfunction was defined as a ratio of early to atrial filling velocity of greater than 1 associated with reversed systolic wave in hepatic venous flow.

Results: Moderate and severe left ventricular diastolic dysfunction increased from preoperatively to 48 hours after coronary artery bypass grafting from 8.2% to 53.7% and from 2.0% to 9.7%, respectively (P < .0001, 48 hours vs preoperatively for both), and the patterns at 6 months were similar to those observed preoperatively. Similar evolution over time was found for right ventricular diastolic dysfunction.

Conclusions: In patients with preoperative left ventricular diastolic dysfunction, biventricular filling patterns are impaired initially but return to preoperative status 6 months after coronary artery bypass grafting.

Publication types

  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Aged, 80 and over
  • Cardiotonic Agents / therapeutic use
  • Coronary Artery Bypass / adverse effects*
  • Coronary Artery Disease / complications
  • Coronary Artery Disease / surgery*
  • Diastole
  • Female
  • Hemodynamics
  • Humans
  • Male
  • Middle Aged
  • Milrinone / therapeutic use
  • Time Factors
  • Ultrasonography
  • Ventricular Dysfunction / diagnostic imaging
  • Ventricular Dysfunction / drug therapy
  • Ventricular Dysfunction / etiology*

Substances

  • Cardiotonic Agents
  • Milrinone