Percutaneous discography: comparison of low-dose CT, fluoroscopy and MRI in the diagnosis of lumbar disc disruption

Eur Spine J. 2006 May;15(5):620-6. doi: 10.1007/s00586-005-1030-3. Epub 2005 Nov 16.

Abstract

Aim: To compare the diagnostic accuracy of low-dose computed tomography (CT), magnetic resonance imaging (MRI) and fluoroscopy in percutaneous discography in patients scheduled for lumbar spondylodesis.

Material and methods: Within a prospective pilot study, 18 disc segments of 11 patients with radicular or pseudoradicular pain prior to anteroposterior spondylodesis were evaluated. After injection of a mixture of non-ionic iodine-containing contrast agent and gadolinium-based contrast medium into the disc spaces, all patients underwent conventional fluoroscopy, as well as low-dose CT and MRI. The occurrence of memory pain during contrast injection was recorded. CT, MRI and fluoroscopic images were analyzed independently by two readers blinded to the clinical findings.

Results: There was 100% agreement between CT and MRI discography in the detection, localization and grading of degenerative changes. In contrast, conventional fluoroscopy identified only 9 of the 12 abnormal segments. Memory pain following puncture was identified in 3 of the 12 affected segments.

Summary: Low-dose CT and MRI discography have a similar accuracy in the assessment of disc disruption and they are superior to fluoroscopic discography.

Publication types

  • Comparative Study

MeSH terms

  • Adult
  • Contrast Media / adverse effects
  • Diskectomy, Percutaneous / methods
  • Female
  • Fluoroscopy / adverse effects
  • Fluoroscopy / methods*
  • Fluoroscopy / standards
  • Humans
  • Intervertebral Disc / diagnostic imaging*
  • Intervertebral Disc / pathology
  • Intervertebral Disc / physiopathology
  • Intervertebral Disc Displacement / diagnosis*
  • Intervertebral Disc Displacement / diagnostic imaging
  • Intervertebral Disc Displacement / physiopathology
  • Lumbar Vertebrae / diagnostic imaging*
  • Lumbar Vertebrae / pathology
  • Lumbar Vertebrae / physiopathology
  • Magnetic Resonance Imaging / adverse effects
  • Magnetic Resonance Imaging / methods*
  • Magnetic Resonance Imaging / standards
  • Male
  • Middle Aged
  • Pain / chemically induced
  • Predictive Value of Tests
  • Preoperative Care / methods
  • Preoperative Care / standards
  • Preoperative Care / trends
  • Radiation Dosage
  • Tomography, X-Ray Computed / adverse effects
  • Tomography, X-Ray Computed / methods*
  • Tomography, X-Ray Computed / standards

Substances

  • Contrast Media