Purpose: To evaluate the degree of contrast enhancement and accuracy of imaging of the circulatory phase in the first-pass, second-pass, and third-pass acquisitions in the pancreato-biliary region with 1-mm collimation obtained by multislice computed tomography (CT).
Materials and methods: In 53 patients, two sequential acquisitions from the porta hepatis to the pancreas were performed during a single breath-hold, followed by a third-pass acquisition including the liver beginning 15 sec after the second-pass acquisition. Contrast enhancement in each acquisition was measured in the aorta, portal vein and its branches, and pancreas. Four experienced radiologists graded using four-point scoring whether or not each acquisition was appropriate for imaging of the arterial phase, pancreatic phase, and portal venous phase.
Results: Aortic enhancement was highest at the beginning of the second-pass acquisition. The portal and splenic veins and pancreas showed maximum enhancement in the second-pass acquisition, while the superior mesenteric vein showed maximum enhancement in the third-pass acquisition. In the visual assessment, significantly higher grades were achieved in the first-pass, second-pass, and third-pass acquisitions with regard to imaging of the arterial phase, pancreatic phase, and portal venous phase, respectively.
Conclusion: Multislice CT permits the acquisition of three distinct circulatory phases (arterial, pancreatic, and portal venous phases) in the pancreatobiliary region with 1-mm collimation.