Impact of dual chamber pacing on the incidence of atrial and ventricular tachyarrhythmias in recipients of implantable cardioverter defibrillators

Pacing Clin Electrophysiol. 2005 Jan:28 Suppl 1:S249-54. doi: 10.1111/j.1540-8159.2005.00002.x.

Abstract

Recent observations suggest that frequent dual-chamber pacing in recipients of implantable cardioverter defibrillators (ICD) may adversely influence clinical outcomes. This prospective, multicenter study examined the relationship between the frequency of atrial (%AP) and ventricular pacing (%VP) and the incidence of atrial (AT) and/or ventricular tachyarrhythmias (VT) in a standard ICD population. A total of 141 consecutive patients with primary and secondary ICD indications were studied. Continuous arrhythmia detection with a dual-chamber ICD revealed paroxysmal AT in 60 (43%) and VT in 72 (51%) patients within 6 months of device implantation. Far-field oversensing of ventricular signals occurred in 13% of all "atrial tachy response" mode switches. Without adjustment for covariates, a higher %AP was associated with an increased incidence of AT (P < 0.05). However, this association remained only weakly significant after adjustment for covariates using a multivariate model. High New York heart failure functional classes correlated significantly with AT (P = 0.02) and VT (P = 0.007). Rate-modulated pacing, programmed in 1/3 of patients, correlated with occurrence of AT (P = 0.006), but not with occurrence of VT. With respect to dual-chamber pacing, a %AP >/= 48% combined with a %VP > 40% was associated with an increased probability for VT. In conclusion, AT and VT occurred frequently within 6 months after dual-chamber ICD implantation. High rates of DDD/R stimulation were associated with a trend toward higher incidence of AT, VT, or both.

Publication types

  • Multicenter Study
  • Research Support, Non-U.S. Gov't

MeSH terms

  • Aged
  • Defibrillators, Implantable*
  • Equipment Design
  • Female
  • Heart Atria
  • Humans
  • Incidence
  • Male
  • Multivariate Analysis
  • Pacemaker, Artificial*
  • Prospective Studies
  • Tachycardia / epidemiology*
  • Tachycardia / prevention & control*
  • Tachycardia, Ventricular / epidemiology
  • Tachycardia, Ventricular / prevention & control*