Sedation algorithm in critically ill patients without acute brain injury

Crit Care Med. 2005 Jan;33(1):120-7. doi: 10.1097/01.ccm.0000150268.04228.68.

Abstract

Objective: To determine whether use of a sedation algorithm to promote a high level of tolerance to the intensive care environment and preserve consciousness affected time to arousal and duration of mechanical ventilation in patients without acute brain injury.

Design: Two-phase, prospective, controlled study.

Setting: University-affiliated medical intensive care unit.

Patients: : Patients without acute brain injury requiring mechanical ventilation for at least 24 hrs.

Interventions: During the control phase, sedatives and analgesics were adjusted according to the physician's decision. During the algorithm phase, sedatives and analgesics were adjusted according to an algorithm developed by a multidisciplinary team including nurses and physicians. The algorithm was based on regular assessments of consciousness and tolerance to the intensive care unit environment using the Adaptation to Intensive Care Environment instrument and was designed to achieve tolerance and maintain a high level of consciousness. Standard practices, including weaning from the ventilator, were the same during both study phases.

Measurements and main results: A total of 102 patients were enrolled (control group, n = 54; algorithm group, n = 48). Median duration of mechanical ventilation was significantly shorter in the algorithm group (4.4 days [interquartile range, 2.1-9.8]) compared with the control group (10.3 days [3.5-17.2], p = .014), representing a 57.3% reduction. In Cox multivariate analysis, the risk of remaining on mechanical ventilation was 0.48 times (95% confidence interval, 0.29-0.78) lower for algorithm patients compared with controls. The median time to arousal was also significantly shorter in patients in the algorithm group (2 days [2-5]) compared with the control group (4 days [2-9], p = .006).

Conclusions: The use of a sedation algorithm to promote tolerance to the intensive care environment and preserve consciousness in patients without acute brain injury resulted in a marked decrease in the duration of mechanical ventilation. This reduction was at least partly attributable to a shorter time to arousal after initiation of mechanical ventilation.

Publication types

  • Clinical Trial
  • Controlled Clinical Trial

MeSH terms

  • Adult
  • Aged
  • Aged, 80 and over
  • Algorithms*
  • Arousal / drug effects
  • Brain Damage, Chronic / therapy*
  • Conscious Sedation / methods*
  • Critical Illness / therapy*
  • Dose-Response Relationship, Drug
  • Drug Administration Schedule
  • Female
  • Fentanyl / administration & dosage
  • France
  • Hospitals, University
  • Humans
  • Infusions, Intravenous
  • Length of Stay
  • Male
  • Midazolam / administration & dosage
  • Middle Aged
  • Pain Measurement
  • Patient Care Team
  • Prospective Studies
  • Respiration, Artificial

Substances

  • Midazolam
  • Fentanyl