Higher order aberrations with aspheric ablations using the Nidek EC-5000 CX II laser

J Refract Surg. 2004 Sep-Oct;20(5 Suppl):S659-62. doi: 10.3928/1081-597X-20040903-04.

Abstract

Purpose: To analyze the change in higher order aberrations in myopic and myopic astigmatic eyes following an aspheric ablation profile for laser in situ keratomileusis (LASIK) using a Nidek EC-5000 CX II excimer laser system.

Methods: We performed a retrospective audit of 38 eyes (19 patients) with myopia and myopic astigmatism. A customized aspheric transition zone profile (CATz) was used in all eyes (profile 4) with an ablation zone of 5 mm and a transition zone of 9 mm using FinalFit software and a Nidek EC-5000 CX II excimer laser system.

Results: Mean higher order aberrations (RMS) increased from 0.42 microm at baseline to 0.57 microm at 6-month follow-up. Mean spherical aberrations (Z12) increased from 0.02 microm at baseline to 0.33 microm after LASIK. Mean spherical aberration defocus equivalent (DEQ) increased from 0.56 microm at baseline to 1.54 at 6 months after surgery. Mean trefoil (Z6) was -0.11 microm at baseline and -0.14 microm at the 3-month examination. Mean coma (Z7) was -0.09 microm at baseline and -0.10 microm after surgery. Mean coma (Z8) was -0.03 at baseline and 0 at the 3-month examination. Mean trefoil (Z9) was -0.03 at baseline and -0.12 at the 3-month examination.

Conclusion: The amount of postoperative higher order aberrations in these myopic eyes was acceptable. However, the clinical significance of these numerical changes in aberrations is not known.

MeSH terms

  • Adult
  • Aged
  • Astigmatism / surgery*
  • Corneal Topography
  • Humans
  • Keratomileusis, Laser In Situ / methods*
  • Middle Aged
  • Myopia / surgery*
  • Postoperative Complications* / diagnosis
  • Refraction, Ocular
  • Retrospective Studies
  • Visual Acuity