Development of monoclonal antibodies for an assay of cardiac troponin-I and preliminary results in suspected cases of myocardial infarction

Clin Chem. 1992 Nov;38(11):2203-14.

Abstract

To improve the specificity of biochemical markers of myocardial infarction (MI), we have developed a double monoclonal "sandwich" enzyme immunoassay to measure cardiac troponin-I (cTnI) in serum. We produced eight IgG monoclonal antibodies against human cardiac troponin-I (cTnI) and tested them against human and animal (canine, bovine, and rabbit) troponins. Five antibodies were cardiac-specific; none of the antibodies were species-specific. Two of the five cTnI-specific monoclonal antibodies were utilized in an immunoassay. Standards were made by adding purified human cTnI to affinity-stripped cTnI-free human sera to cover the range 0-100 micrograms/L for cTnI. The dose-response curve was nonlinear but reproducible. Total assay imprecision (CV) varied between 11% and 21%. The upper limit of the reference range (nonparametric 95% interval) was established as 3.1 micrograms/L by measuring cTnI concentration in sera of 159 hospitalized patients without evidence of cardiac disease. Purified human skeletal TnI up to 10,000 micrograms/L did not affect the assay (calculated cross-reactivity < 0.1%). Diagnostic sensitivities of creatine kinase MB isoenzyme (CK-MB) and cTnI were evaluated retrospectively in 49 consecutive patients with proven MI. In the 30 patients for whom sufficient information was available to establish an accurate time course, CK-MB was more sensitive during the first 4 h after the onset of chest pain, but thereafter the sensitivities were similar up to 48 h. However, cTnI is more cardiac-specific than is CK-MB and remains increased longer than does CK-MB.

Publication types

  • Research Support, Non-U.S. Gov't
  • Research Support, U.S. Gov't, P.H.S.

MeSH terms

  • Amino Acid Sequence
  • Animals
  • Antibodies, Monoclonal* / biosynthesis
  • Antibodies, Monoclonal* / immunology
  • Antibody Specificity
  • Binding, Competitive
  • Cattle
  • Dogs
  • Enzyme-Linked Immunosorbent Assay / statistics & numerical data
  • Humans
  • Hybridomas / immunology
  • Immunoassay* / statistics & numerical data
  • Immunoblotting
  • Immunoglobulin G / immunology
  • Mice
  • Molecular Sequence Data
  • Myocardial Infarction / blood*
  • Myocardium / chemistry*
  • Quality Control
  • Rabbits
  • Reference Values
  • Retrospective Studies
  • Troponin / blood*
  • Troponin I

Substances

  • Antibodies, Monoclonal
  • Immunoglobulin G
  • Troponin
  • Troponin I