Abstract
To compare the ototoxicity of amikacin and netilmicin, tone audiometry, high-frequency audiometry, early auditory evoked potentials, and evoked otoacoustic emission testing were used to evaluate 30 patients (15 under amikacin and 15 under netilmicin). Ototoxicity was not significantly different in the two groups.
Publication types
-
Clinical Trial
-
Comparative Study
-
Controlled Clinical Trial
-
English Abstract
-
Randomized Controlled Trial
MeSH terms
-
Adult
-
Amikacin / pharmacology
-
Amikacin / therapeutic use
-
Amikacin / toxicity*
-
Audiometry / methods*
-
Evoked Potentials, Auditory / drug effects*
-
Humans
-
Middle Aged
-
Netilmicin / pharmacology
-
Netilmicin / therapeutic use
-
Netilmicin / toxicity*
-
Reference Values