Condenser-type diffusion denuders for the collection of sulfur dioxide in a cleanroom

Anal Bioanal Chem. 2003 Feb;375(3):456-9. doi: 10.1007/s00216-002-1682-3. Epub 2003 Jan 16.

Abstract

High-efficiency condenser-type diffusion denuders of cylindrical and planar geometries are described. The film condensation of water vapor onto a cooled denuder surface can be used as a method for collecting water-soluble gases. By using SO(2) as the test gas, the planar design offers quantitative collection efficiency at air sampling rates up to 5 L min(-1). Coupled to ion chromatography, the limit of detection (LOD) for SO(2) is 0.014 ppbv with a 30-min successive analysis sequence. The method has been successfully applied to the analysis of temperature- and humidity-controlled cleanroom air.

MeSH terms

  • Air Pollutants / analysis
  • Air Pollutants / isolation & purification
  • Air Pollution / prevention & control
  • Automation
  • Chromatography / instrumentation
  • Chromatography / standards
  • Environment, Controlled*
  • Equipment Design
  • Occupational Exposure / prevention & control
  • Occupational Exposure / standards
  • Sensitivity and Specificity
  • Sulfur Dioxide / analysis
  • Sulfur Dioxide / isolation & purification*

Substances

  • Air Pollutants
  • Sulfur Dioxide