Low-dose dobutamine stress gated SPET for identification of viable myocardium: comparison with stress-rest perfusion SPET and PET

Eur J Nucl Med Mol Imaging. 2002 Jul;29(7):882-90. doi: 10.1007/s00259-002-0795-4. Epub 2002 Apr 13.

Abstract

The detection of viable myocardium is important for the prediction of functional recovery after revascularisation. However, a fixed perfusion defect often includes viable myocardium, and perfusion imaging then underestimates myocardial viability. We previously reported that low-dose dobutamine stress gated single-photon emission tomography (SPET) provides similar findings to dobutamine stress echocardiography in the assessment of myocardial viability. The present study investigated whether low-dose dobutamine stress gated SPET is of additional value as compared with stress-rest technetium-99m tetrofosmin SPET for the detection of myocardial viability. Standard stress-rest perfusion SPET, low-dose dobutamine stress gated SPET and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG PET) were studied in 23 patients (mean age 67+/-7.6 years) with previous myocardial infarction. Twenty-one of them were successfully studied with each technique. FDG PET viability (FDG uptake >/=50%) was employed as the gold standard. One-day stress-rest (99m)Tc-tetrofosmin myocardial SPET was performed. After the resting study, gated SPET was acquired following infusion of 7.5 microg kg(-1) min(-1) of dobutamine. Left ventricular wall motion in 16 segments was assessed by cine mode display using a four-point scale. Myocardial viability was considered present when there was improvement by one point. Of a total of 336 segments analysed, 53 had persistent defects on stress-rest perfusion SPET. FDG viability was seen in 16 of 17 dobutamine-responsive segments, but in only 11 of 36 dobutamine non-responsive segments ( P<0.01). Thus, in the segments with persistent defects, viability findings on low-dose dobutamine stress gated SPET were concordant with those on FDG PET in 77% of segments (kappa value =0.55). For the detection of FDG-viable myocardium, the combination of stress-rest perfusion SPET and low-dose dobutamine stress gated SPET achieved a better sensitivity than stress-rest perfusion SPET alone (35/46, 76% vs 19/46, 41.3%, P<0.001), with a similar specificity (25/29, 86% vs 26/29, 90%, P=NS). We conclude that in the identification of viable myocardium, low-dose dobutamine stress gated SPET may provide additional information missed on a routine stress-rest perfusion scan. Dobutamine stress gated SPET may provide new insights into myocardial viability on the basis of ischaemia and contractile reserve.

Publication types

  • Clinical Trial
  • Comparative Study

MeSH terms

  • Aged
  • Dobutamine* / administration & dosage
  • Exercise Test
  • Female
  • Fluorodeoxyglucose F18*
  • Gated Blood-Pool Imaging / methods*
  • Heart / diagnostic imaging
  • Heart / physiopathology
  • Humans
  • Male
  • Myocardial Infarction / diagnostic imaging*
  • Myocardial Infarction / physiopathology*
  • Organophosphorus Compounds*
  • Organotechnetium Compounds*
  • Prospective Studies
  • Radiopharmaceuticals
  • Sensitivity and Specificity
  • Tomography, Emission-Computed
  • Tomography, Emission-Computed, Single-Photon / methods
  • Ultrasonography

Substances

  • Organophosphorus Compounds
  • Organotechnetium Compounds
  • Radiopharmaceuticals
  • Fluorodeoxyglucose F18
  • Dobutamine
  • technetium tc-99m tetrofosmin