FDG-PET for detection of recurrences from malignant primary bone tumors: comparison with conventional imaging

Ann Oncol. 2002 Jan;13(1):157-60. doi: 10.1093/annonc/mdf012.

Abstract

Background: The aim of this study was to assess the diagnostic ability of positron emission tomography using 2-[fluorine-18]fluoro-2-deoxy-D-glucose (FDG-PET) in the detection of recurrences from malignant primary bone tumors compared with conventional imaging.

Patients and methods: In 27 patients (6 osteosarcomas, 21 Ewing's sarcomas), 41 FDG-PET examinations performed for diagnosis or exclusion of recurrent disease were evaluated. Conventional imaging techniques consisted of magnetic resonance imaging of the primary tumor site, thoracic computed tomography, and Tc-99m methylene diphosphonate bone scintigraphy. The reference methods were the histopathological analysis and/or the clinical and imaging follow-up.

Results: In 25 examinations reference methods revealed 52 sites of recurrent disease (local n = 7; distant: osseous n = 22, pulmonary n = 13, soft tissue n = 10). On an examination-based analysis FDG-PET had a sensitivity of 0.96, a specificity of 0.81 and an accuracy of 0.90. Corresponding values for conventional imaging were 1.0, 0.56 and 0.82.

Conclusions: The sensitivity, specificity and accuracy of FDG-PET in the detection of recurrences from osseous sarcomas are high. On an examination-based analysis, FDG-PET had a not significantly lower sensitivity in comparison with conventional imaging. However, FDG-PET showed a small advantage in the detection of osseous and soft-tissue recurrences compared with conventional imaging.

Publication types

  • Clinical Trial
  • Comparative Study

MeSH terms

  • Adolescent
  • Adult
  • Biopsy
  • Child
  • Female
  • Fluorodeoxyglucose F18*
  • Humans
  • Magnetic Resonance Imaging
  • Male
  • Neoplasm Metastasis
  • Neoplasm Recurrence, Local / diagnosis*
  • Neoplasm Recurrence, Local / pathology
  • Neoplasms, Bone Tissue / diagnosis*
  • Neoplasms, Bone Tissue / pathology
  • Recurrence
  • Tomography, Emission-Computed / methods*

Substances

  • Fluorodeoxyglucose F18