Open surgical repair for a perigraft leak after endovascular stent-graft emplacement of descending thoracic aneurysm

Jpn J Thorac Cardiovasc Surg. 2001 Oct;49(10):618-20. doi: 10.1007/BF02916226.

Abstract

Although transluminal stent-graft implantation is less invasive for treating an aneurysm in the thoracic descending aorta, this technique is not always successful. Here, we report two cases of a perigraft leak identified after stent-graft deployment, and complete occlusion of the leak could not be attained by additional stent-graft deployment. Open surgical repair using a stented graft was performed through a median sternotomy without opening the left pleura. This procedure should be considered as one of the less-invasive techniques for treating a perigraft leak after endovascular stent-graft emplacement.

Publication types

  • Case Reports

MeSH terms

  • Aged
  • Aorta, Thoracic / surgery
  • Aortic Aneurysm, Thoracic / surgery*
  • Equipment Failure
  • Humans
  • Male
  • Reoperation
  • Stents*
  • Sternum / surgery
  • Thoracic Surgical Procedures / methods