Purpose: To 1) assess the potential of magnetization transfer (MT)-weighted MR imaging to improve the often poor visibility of native kidneys in patients with a renal transplant; and 2) compare low-field MR imaging and ultrasonography (US) for imaging these fibrotic kidney remnants.
Material and methods: Seventy-two native kidneys of 36 patients were prospectively evaluated with US and MR. In low-field (0.1 T) MR imaging, T1-, T2- and MT-weighted sequences were used. MT-weighted images were compared with T2-weighted images in their ability to delineate the kidneys from their surroundings whereas US and MR were compared for detection of renal cysts and possible solid tumors.
Results: MT-weighted images proved superior to conventional T2-weighted images in producing contrast between the kidney remnants and their fatty surroundings. Although US revealed a few small renal cysts that were not seen at MR images, no statistical difference was found between the two modalities in this respect.
Conclusion: MT imaging, due to its unique protein-specific signal depression, offers significantly improved visualization and delineation of end-stage kidneys. US, because its better availability and cost-benefit ratio, remains the method-of-choice compared to low-field MR imaging in detecting cysts in multicystic kidneys. MR investigation is helpful in selected patients and may be used as an alternative.