Development and assessment of ELISA for serodiagnosis of HIV-infection

Southeast Asian J Trop Med Public Health. 1998 Dec;29(4):763-6.

Abstract

A home-made ELISA for serodiagnosis of HIV-infection was developed. It made use of the HIV viral lysate to coat on ELISA microplates. The purpose was to establish an ELISA for serodiagnosis of HIV-infection. The newly-developed ELISA, "H-ELISA", was applied to test 792 samples of HIV-positive serum as confirmed by Western blot. All 792 samples were positive by H-ELISA. It was also applied to test 540 samples of normal sera obtained from different laboratories in Srinagarind Hospital. A number 530 normal sera was negative, 8 samples were positive and confirmed by Western blot and 2 samples were false positive. It was concluded that the H-ELISA possessed 100% sensitivity with a false positive rate of 2/532(0.38%). The H-ELISA, the cost/test was less than 5 bahts, appears to be promising for substitution of imported commercial kits.

Publication types

  • Clinical Trial
  • Comparative Study
  • Controlled Clinical Trial
  • Research Support, Non-U.S. Gov't

MeSH terms

  • AIDS Serodiagnosis / economics
  • AIDS Serodiagnosis / methods*
  • Agglutination Tests
  • Blotting, Western
  • Cost Control
  • Enzyme-Linked Immunosorbent Assay / economics
  • Enzyme-Linked Immunosorbent Assay / methods*
  • Humans
  • Sensitivity and Specificity